Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. Elite. Can breaker be bad? You need extreme care in this next step. It worked for a day but the day after it didnt work. Turn the power off at the breaker box and carefully remove the wires to the clock. Any advice on how to fix. As an Amazon Associate we earn from qualifying purchases. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. My pool pump timer is not working properly. The trippers will "trip" the analog clock to turn on and off automatically at the set times. Reset the clock on the timer to the correct time to get it back to the desired on/off times. This will disengage the dial from the . The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. 1-48 of 242 results for "pool timer trippers" RESULTS. I can turn the pool pump on via the manual power lever thats located at 5 O clock on the timer. I have a Model T104P and have a new green on tripper attached. Then after a bit, the pump restarts. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. Any other thoughts? #9. Pool pump comes on fine with the on dog, but wont turn off. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. I notice my pool pump was not on so I went and I hear timer running but no juice to the pool filter. My original timer worked for 5 years then the clock stopped and I heard no sound. The problem lies, where the power dies, as they say, Thanks for the response. But first, pull the mechanism from the box by releasing the tab at the top (be sure breaker is turned off, first), and inspect the gears and copper tabs on the back, to look for something clogging up the works, insects, lizards, sand, etc. Take them off and inspect them and look for twists in them. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. We cover T101, T103 and T104 models of mechanical pool timers. AJH Trade Group is a participant in the Amazon Services LLC Associates Program. Donna Simpson Eating Website But What Toilet? If you cant see an issue with the gears, then it could be the timer motor. Not sure if i need to check out the wiring, but it is a bit frustrating. Is it Necessary? If it doesnt, there could be an issue with the clock face or gears. Refer to the wiring diagram on the timer door for more information. Any ideas? After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. Is there a control board, PCB in the panel that could have problems? I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? If you cant, is the manual switch stuck or jammed? Trippers are not installed properly Re-install trippers on dial 2. Hi Jere, that could be the timer motor failing. Followed all directions and even watched YouTube troubleshooting videos. Leave the paper inside your timer box so that you do not mistakenly misplace it. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. I can, however, hear an intermittent click as if the mechanism is trying to switch on. You can replace the entire mechanism or the gears. Required fields are marked *. Hello. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. }
. Paul, it could be that you got a 50hz motor, instead of a 60hz? Thank you so much. You need that 8 hr run in just the summer . Hi there, It is generally not recommended to reuse a critical fastener like the rear spinal nut on your 2000 Ford Focus. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . Sometimes the trippers get loose or damaged. Timer not tripping pump on. Tighten down all brass screws securely, to hold all wires firmly in place. Step 3 Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. Push the tab on the top, and let the mechanism fall forward. "@type": "ImageObject",
The trippers push on a tab on the on/off switch. The clock not turning on your Intermatic pool timer is a common issue. So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. Flip it from where it is now, to the opposite side. What do you suggest to do to get the cover up and the pillows back into position. DEWENWILS Outdoor Outlet Box. But of the timer itself is bad you will need a licensed electrician to change the timer for you. If all looks well, and the gears are still not turning, you may need to replace the mechanism. my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. Thanks for your help! I have replaced the trippers, but the problem persists. Or there could be a bad relay in the control panel, if you have ice cube style relays. Could I send you a picture of my setup? "
Power surges could be to blame. I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. Is there a separate switch somewhere between breaker and timer? Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. My intermatic timer is not turning my pool pump on. Jul 20, 2021. Black goes to _1 The timer appears to be working fine (keeps time). May we present Speed Tripper, the second pedal collaboration from Death By Audio and LEVITATION. Grab it, pull it towards you, move it around then place it back down.
Now, Im going to order some additional timer clips. The works fine and keeps time while it is on but the second it turns the filter off, it stops keeping time and the cogs stop moving. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. Can I spray the timer while there is electricity going in the timer box? Can I wire this timer to an outlet or should I search for another solution? Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. I have Model T40004RTe. Other problems causing this could be the yellow clock dial isnt located correctly, wiring is loose, the gears are stripped, damaged or partially jammed or even the clock motor. Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. I replaced my pool timer a couple of months ago with a Tork 1109A mechanical 240v timer. Hi, Davy, seeing lots of complaints here. Your incoming power leads should connect to terminals 1 and 3, and the wires that lead to the pump, should be connected to terminals 2 and 4. When the power goes out, the timer stops. Only perform this step if you are qualified. I am having the same problem. I dont see timer gears rotating on any power going to the pump or salt system. The terminals on the wires aren't tight. If its not, then the timer will not turn on/off at the correct times. With the power switched off at the breaker, take out the main part of the timer and carefully inspect the gears for obstructions and missing teeth. However, intermittently after the ON tripper switches pump on the pump will stop. For Sale: 2 beds, 2 baths 1152 sq. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. Check out our online selection of new Intermatic timer clocks at InTheSwim.com! If you loosen the hold down screw to much it could separate from the timer pin. Still no luck. http://waterheatertimer.org/Tork-timers-and-manuals.html It only takes a small amount of dirt to foul up gears so look carefully. Any ideas? In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Just installed a new timer. Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. "logo": {
If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. i would like to use a timer but am now afraid to try another. Second thing to check is the dial bent or warped, in that area where the on tripper is? You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. Set the current time to the center time pointer, pointing downward at 6 oclock. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. If I have to tell you which terminals to measure, you shouldnt be doing this! I hope this helps. I visually checked the clock motor and it was good. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. This site is owned and operated by AJH Trade Group. Hi Mike, yes I sent you an email to your yahoo acct. Gold OFF tripper works for all models. If the pool timer is not keeping the correct time or losing time, there may be a simple fix. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. AJH Trade Group also participate in other affiliate programs. "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. "height": "219",
On mine, the gears behind the dial look metal, but the motor (behind the plate) they look plastic (maybe?) Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. The timer quit after a nearby lightning strike. The on/off pins are tight and pretty new stillany thoughts? Not sure if you still answer these but I have a weird one for you. Tighten them with a wrench. I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. Partially loosen the screw that holds the "off" pin in place. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . View community ranking In the Top 5% of largest communities on Reddit. It would not reset itself and could not get power back to the timer. And when switched on, power to the load terminals? If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. Read full answer 2/14/2023 3:20:07 AM "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The capacitor for the motor may be bad. },
Pool co says T104 timer needs replacement and filter cartridge. Is it possible to do this by loosening the timer screw a bit? Second thing to check is the dial bent or warped, in that area where the on tripper is? Hello, newer pool guy here. Hi Rhomell, are you sure you got the correct trippers? You should always be able to switch your pump on and off manually at the timer. My time clock has an ant infestation! Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. My intermatic pool timer will not automatically turn on. Or be loose and not making good contact. Generally, plug-in-outlet timer has gone bad, then it cannot be fixed. Any advice? If the pump doesnt come on, follow the steps below. Wired correctly, #10 wire, nothing. VIDEO TOUR. Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. hi, I have a smart pump for my pool, the time clock turns on in the morning and at the same time I see that the pump has power but it doesnt turn on, I have to turn on manually, is it something that the electrician has to connect to the pump so they are synchronized? Reference Manual & Buyer's Guide Another Brick in the Hi, I got the same problem as my clock not working. Ft. 750 Joshua Dr, Hollister, CA 95023. "height": "219",
Is that a faulty motor? Once you have the timer set to the correct time you then can loose the little hold down screw on both the timer on and timer off pins. Terminals 2 and 4 are used for wires going to the load (pump). My pump has a plug. Resolved! So out comes the soldering gun and the shrink wraps and that did the trick. You will have live wires exposed and they can kill you if you touch them. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. We had a few power outages the last couple of weeks, but Ive reset the time and it continues to lose time. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. Open following links to identify timer and then add a comment. The pool was running on a timer. When the trippers are done up, you shouldnt be able to move them with your hands. Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. not sure what is the problem. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. },
), you should be able to discern if this is the problem, which could mean a new clock. We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. I just replaced my T101 timer 2 years ago. If not, that sounds like a weak/bad motor. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveller reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. The pump worked perfectly before I unscrewed it. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. Then number(time of day) that you line up with the time marker will be the time that you are setting your timer to. Jump to the troubleshooting steps below to fix the issue. If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. Turn the metal bar until it contacts one of two plastic side tabs. Manual switch works my aerator. Confused. It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. If it doesnt improve, inspect the contacts behind the time clock for insect infestation. Hi Carlos, is there a GFCI outlet in the circuit? You can find this in your power board. No broken or loose wires visible. what causes timer on/off pins to bend and how can i prevent timer pins from bending. Watch these tips and tricks before replacing it. It just stays at that time. My clock seems to work but but the on and off switch does not turn on the pool pump. I manually turn it on timer is running, it will trip pump OFF. Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). If you look closely (with a flashlight and your glasses! We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. If not, the motor may be failing. "image": {
we purchased the house 5 years ago so not sure how old the timer is? Theres really only 3 causes as to why your pump wont turn on/off. Hi Ryan, that sounds like a bad motor or a broken gear, you can replace just the motor, or the entire clock mechanism. Reasons Why Pool Timers Stop Working 1. Ill do the same. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Your timer is on a 24-hour cycle. "@type": "ImageObject",
Just turn the timer wheel until the correct time of the day is aligned with the timer marker that is mounted in front of the wheel. I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. MLS # 6354744 For Do-it-Yourself pool owners like yourself to make simple,, Sure, you could just replace your entire Hayward pump, but replacing only the motor is just as easy, and you don't have, Millivolt Pool Heater Troubleshooting Guide, https://www.intheswim.com/p/2-circuit-pool-timer, https://www.intheswim.com/p/24-hour-pump-timer, https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf. Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. Ive reset the time 5 times and just realized that its going counter clockwise. It should loosen up after a few goes when the grease and gunt dissolve. Watch these tips and tricks before replacing it. If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. Other causes include rusted springs, insect infestation and loose timer dogs. It is an ON tripper right? It is still moving and it will trip off but not on. Does the tripper work on other areas of the clock, like near the off tripper? No luck. Hello have a question some what related. Related Reading: Should You Get a Pool Pump Timer? If you look closely, you should be able to discern if this is the problem, which could mean a new clock. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. It was always fine before.